Welcome to Nuclear Fusion and Plasma Physics, Today is Share:

NUCLEAR FUSION AND PLASMA PHYSICS ›› 2017, Vol. 37 ›› Issue (2): 194-198.DOI: 10.16568/j.0254-6086.201702011

• Nuclear Fusion Engineering and Technology • Previous Articles     Next Articles

EAST共振磁扰动线圈电源响应延迟分析及优化

CHEN Kun, GAO Ge   

  1. (Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031)
  • Received:2016-04-06 Revised:2017-01-05 Online:2017-06-15 Published:2017-06-14

EAST共振磁扰动线圈电源响应延迟分析及优化

陈 坤,高 格*   

  1. (中国科学院等离子体物理研究所,合肥 230031)
  • 作者简介:陈坤(1990-),男,贵州遵义人,硕士研究生,主要研究方向为大功率快速控制电源。
  • 基金资助:

    国家磁约束核聚变能发展研究专项(2011GB109002)

Abstract:

In order to improve response speed and output characteristics of resonant magnetic perturbations (RMP) coil power supply of EAST tokamak, the response time delay is analyzed and optimized. Time delay that is caused by symmetrical rules sampling and single polarity PWM is amply analyzed and quantitatively determined. And multiple sampling & tardive updating is proposed to improve inverter response delay. The experimental data demonstrates that response time delay is decreased from 206μs to 70μs by the method, which meets the requirement of EAST experiments.

Key words: EAST, RMP, Response delay, Multiple sampling &, tardive updating

摘要:

为了提高EAST装置中共振磁扰动(RMP)线圈电源的输出电压、电流响应速度和输出特性,对共振磁扰动线圈电源的响应时间延迟进行了分析和优化处理。详细分析了对称规则采样和单极性倍频PWM调制过程所产生的时间延迟,针对该部分时间延迟提出了多次采样延时数据更新方法,对逆变电源控制器进行优化和改进。实验结果表明,采用该方法后电源输出响应时间延迟从206μs减小为70μs,可以满足EAST实验的需求。

关键词: EAST, 共振磁扰动, 响应延迟, 多次采样延时数据更新

CLC Number: