Simulation on heat transfer of new type lower divertor in EAST

XU Hou-chang, LI Lei, YAO Da-mao, ZHOU Zi-bo, CAO Lei, Xu Tie-jun, HAN Le, ZI Peng-fei   

  1. (1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031; 2. University of Science and Technology of China, Hefei 230026; 3. Department of Mechanical Engineering Hefei University, Hefei 230601)
  • Received:2018-03-26 Revised:2018-12-10 Online:2019-06-15 Published:2019-06-13

EAST新型下偏滤器冷却结构 传热性能数值模拟

徐厚昌1, 2, 3,李 磊*1,姚达毛1,周自波1,曹 磊1, 许铁军1,韩 乐1,訾鹏飞1, 2   

  1. (1. 中国科学院等离子体物理研究所,合肥 230031; 2. 中国科学技术大学,合肥 230026; 3. 合肥学院机械工程系,合肥 230601)
  • 作者简介:徐厚昌(1976-),男,安徽合肥人,汉族,博士研究生,主要从事核能科学与工程及机械设计研究。
  • 基金资助:

    国家重点研发计划项目(2017YFA0402500);合肥学院教学研究项目(2018hfjyxm47)

Abstract:

A new water-cooled tungsten lower divertor was designed to replace the present carbon lower divertor in EAST to fit the heat flux up to 10MW·m-2 under a 400s long pulse and high β H-mode plasma operation. Based on the heat transfer simulation of the lower divertor, an advanced water-cooled structure for the lower divertor was proposed after several cooling structures were studied. According to the analysis, the divertor model of EAST which meets the requirements of heat transfer is established.

Key words: EAST, Plasma, Tungsten divertor, Water-cooled, Heat transfer

摘要:

为实现EAST装置超400s长脉冲高约束模、10MW加热功率下的稳态运行,需对现有的下碳偏滤器进行升级改造,拟采用钨串结极水冷却系统,热通量控制在水冷钨铜第一壁材料允许的稳态的10MW·m-2。在对下钨偏滤器的冷却结极传热性能进行数值模拟仿真研究的基础上,研究了多种以钨串单元为基础的冷却结极,提出了一种新型下钨偏滤器水冷结极设计,幵建立了满足传热要求的EAST装置新型下钨偏滤器单元结构模型。

关键词: EAST, 等离子体, 钨偏滤器, 水冷, 传热分析