Welcome to Nuclear Fusion and Plasma Physics, Today is Share:

NUCLEAR FUSION AND PLASMA PHYSICS ›› 2007, Vol. 27 ›› Issue (3): 203-207.

• Research Report • Previous Articles     Next Articles

Calculation of electrode cooling in glow discharge on ITER

ZENG Jian-er, ZOU Gui-qing, RANG Hong   

  1. (Southwestern Institute of Physics, Chengdu 610041)
  • Received:2007-01-12 Revised:2007-04-09 Online:2007-09-15 Published:2011-08-15

ITER 辉光放电电极的冷却计算

曾建尔,邹桂清,冉 红   

  1. (核工业西南物理研究院,成都 610041)
  • 作者简介:曾建尔(1953-),福建省龙岩市人,研究员,现在核工业西南物理研究院从事ITER相关设计工作。

Abstract:

The calculated results for cooling electrode based on the previous design are presented. When the power is 9000W in glow discharge conditioning, the temperature of electrode cooled by water with speed of 4~6 m•s-1 will not be over 100°C, and the temperature will not be over 200°C when the electrode is cooled by Helium with speed of 300m•s-1. The calculation shows that cooling by water is more efficient than by Helium.

Key words: Glow discharge, Electrode, Cooling calculation

摘要:

对清洗放电时ITER 辉光放电电极采用水冷和气冷条件下的电极冷却进行了计算。当辉光放电清洗功率为9000W,冷却水的流速为4~6m•s-1,入口温度为室温25°C时,电极的温升不会超100°C。当冷却媒介为氦(He),速度为300m•s-1,入口温度为室温25°C时,最高温度不会超过200°C。计算表明,当仅仅考虑因辉光放电电功率所导致电极发热时,水冷可以满足电极辉光放电时的冷却要求。

关键词: 辉光放电, 电极, 冷却计算

CLC Number: