Welcome to Nuclear Fusion and Plasma Physics, Today is Share:

Nuclear Fusion and Plasma Physics ›› 2021, Vol. 41 ›› Issue (1): 37-44.DOI: 10.16568/j.0254-6086.202101007

• Nuclear Fusion Engineering and Technology • Previous Articles     Next Articles

Preliminary design and analysis of CFETR He-cooled divertor 

HUANG Wen-yu, LU Yong, ZHANG long, LIU Kuan-cheng, JIN Yu-zhong, ZHENG Guo-yao, CAI Li-jun, ZHU Yun-peng, XUE Miao #br#   

  1. (Southwestern Institute of Physics, Chengdu 610041) 

     
  • Received:2019-07-05 Revised:2020-06-20 Online:2021-03-15 Published:2022-01-20

CFETR 氦冷偏滤器初步设计与分析

黄文玉,卢  勇,张  龙,刘宽程,金羽中, 郑国尧,蔡立君,朱运鹏,薛  淼 
  

  1. (核工业西南物理研究院,成都 610041) 
  • 作者简介:黄文玉(1992−),男,四川巴中人,硕士,实习研究员,现主要从事托卡马克装置冷却技术研究。
  • 基金资助:
    国家磁约束核聚变能发展研究专项(2017YFE0300503) 

Abstract: Based on the configuration of divertor of China fusion engineering test reactor (CFETR), T-type, 
finger-like and slab models of He-cooled divertor were preliminarily designed. Under the condition of 10MPa 
inlet helium pressure and 10MW⋅m−2 steady-state heat load, numerical analysises of their heat transfers were 
carried out. By optimizing the structural design and inlet helium parameters, the working temperature of the target 
plate was reduced and the ability of the target plate to handle high thermal load was improved. Under the 
steady-state heat load of 20MW⋅m−2, the optimized elementary units of T-type and finger-like structures were 
analyzed. Consequently, the preliminary structure of hybrid CFETR He-cooled divertor was proposed. 

Key words: CFETR, Divertor, He-cooled, High thermal load, Composite construction 

摘要: 基于中国聚变工程试验堆(CFETR)偏滤器位形,初步设计了指状、平板和 T 形三种氦冷偏滤器模型,
在 10MPa 入口氦压力、10MW⋅m−2 稳态热负荷下,分别对其进行传热数值分析。通过优化结构设计和氦入口参数,
降低了靶板工作温度,探索了三种单元结构靶板处理高热负载的能力。在 20MW⋅m−2 的稳态热负荷下,对优化后
的 T 形和指状单元结构进行了受热分析,并由此提出了混合型 CFETR 氦冷偏滤器初步结构。 

关键词: CFETR;偏滤器;氦冷;高热负荷;混合结构 

CLC Number: