Welcome to Nuclear Fusion and Plasma Physics, Today is Share:

NUCLEAR FUSION AND PLASMA PHYSICS ›› 2015, Vol. 35 ›› Issue (4): 302-307.DOI: 10.16568/j.0254-6086.201504003

• Plasma Physics • Previous Articles     Next Articles

Design of ERD diagnostic system on EAST tokamak

LI Ying-ying1, YIN Xiang-hui2, ZHANG Yi2, FENG Shuang-yuan2, FU Jia1, Lü Bo1   

  1. (1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031; 2. School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026)
  • Online:2015-12-15 Published:2015-12-15

EAST 装置上ERD 光谱诊断系统设计

李颖颖1,尹相辉2,张 镱2,冯双圆2,符 佳1,吕 波1   

  1. (1. 中国科学院等离子体物理研究所,合肥 230031;2. 中国科学技术大学核科学技术学院,合肥 230026)
  • 作者简介:李颖颖(1983-),女,山东聊城人,博士,助理研究员,主要从事可见光多普勒光谱诊断研究。
  • 基金资助:

    国家自然科学基金(11405212,11175208);国家磁约束核聚变能发展研究专项资助项目(2013GB112004, 2012GB101001)

Abstract:

A new edge rotation diagnostic system (ERD) was developed to measure the edge plasma rotation velocities and ion temperature profiles toroidally and poloidally. The collective optics adopts the ‘plug-in’ concept and is very flexible for additional system adjustment and maintenance after installation. For the spectrometer, a multi-slit entrance is used to effectively improve the capacity of the spectrometer and accommodate more optical fibers. A back-illuminated EMCCD is adopted as the photon detector for its high sensitivity and wide dynamic range. The high OH-radical concentration fused silica fibers are adopted to resist the neutron radiation. The system is in the visible wavelength range (350~800nm), the achieved temporal and spatial resolution is 15ms and 1cm respectively. Experimental results during the LHW phase are consistent with the collaborative experimental results from the XCS and fast reciprocating probe.

Key words: EAST tokamak, ERD diagnostic, Ion temperature, Rotation velocity

摘要:

在EAST 装置上研制了一套边界旋转测量系统(ERD)用于测量边界等离子体环向/极向旋转速度和离子温度分布。前置收光系统采用了嵌入式(plug-in)结构,便于系统调试与维护。光谱仪设计成多入射狭缝结构,可容纳更多的光纤,提高了其利用率。探测器选用了高灵敏度和高动态范围的电子倍增CCD(EMCCD)探测器。使用了含高OH 基浓度的石英光纤,可以承受一定剂量的中子辐射。系统设计的测量波段为350~800nm,最高时间分辨为15ms,空间分辨为1cm。低杂波注入下的实验结果与早期EAST 上二维弯晶谱仪与快速往复探针联合实验的结论一致。

关键词: EAST装置, ERD诊断, 离子温度, 旋转速度

CLC Number: