NUCLEAR FUSION AND PLASMA PHYSICS ›› 2010, Vol. 30 ›› Issue (4): 360-364.
• Nuclear Fusion Engineering and Technology • Previous Articles Next Articles
DAI Xiao-jing, SHEN Biao, LIU Guang-jun
Received:
Revised:
Online:
Published:
戴晓静,沈飙,刘广君
作者简介:
基金资助:
国家自然科学基金资助项目(10835009);中国科学院知识创新工程重要方向性项目(KJCX3.SYW.N4)
Abstract:
In order to calibrate the offset of the magnetic probe position and loop gain of the electromagnetic measurement system in EAST tokamak, the discharge mode of the poloidal field coils is designed through the analysis of the error sources.The measurement data is preprocessed by Green function, then using the simplified Taylor linear expansion ideas, combined with least squares method with weights, the offset of the magnetic probe position and the loop gain is fitted after cycle-iteration. Experimental results show that this calibration method is reasonable.
Key words: Electromagnetic measurement, Error analysis, Green function, Taylor expansion, Least squares
摘要:
为了标定EAST装置电磁测量系统中的磁探针位置偏差和回路增益,通过分析该装置中的误差源,设计了极向场线圈的通电模式。运用格林函数等算法程序对测量数据进行预处理,利用简化的泰勒线性展开,结合带权重的最小二乘法对数据进行多次循环迭代,拟合出磁探针的位置偏差和回路增益。实验结果表明,使用该方法标定是合理的。
关键词: 电磁测量, 误差分析, 格林函数, 泰勒展开, 最小二乘法
CLC Number:
TL65+5
DAI Xiao-jing, SHEN Biao, LIU Guang-jun. Calibration of magnetic probe parameters[J]. NUCLEAR FUSION AND PLASMA PHYSICS, 2010, 30(4): 360-364.
戴晓静,沈飙,刘广君. 磁探针参数的标定[J]. 核聚变与等离子体物理, 2010, 30(4): 360-364.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hjby.ac.cn/EN/
https://www.hjby.ac.cn/EN/Y2010/V30/I4/360
[1] 项志遴, 俞昌旋. 高温等离子体诊断技术(上册)[M]. 上海: 上海科学技术出版社. 1982.
[2] 沈飙. EAST电磁测量诊断研究[D]. 合肥: 中国科学院等离子体物理研究所, 2007.
[3] 奚维斌, 武松涛, 沈飙, 等. EAST装置的磁探针设计[J]. 核聚变与等离子体物理, 2008, 28(1): 73-76.
[4] 陈汤铭. 电感计算手册[M]. 北京: 机械工业出版社, 1986.
[5] 钱金平. EAST平衡反演及垂直不稳定性研究[D]. 合肥: 中国科学院等离子体物理研究所, 2008.
[6] 赵皖平, 罗家融, 黄勤超. 基于HT-7U超导托卡马克放电的EFUND软件实现[J]. 核聚变与等离子体物理, 2004, 24(2): 107-110.