NUCLEAR FUSION AND PLASMA PHYSICS ›› 2006, Vol. 26 ›› Issue (1): 27-30.
• Contents • Previous Articles Next Articles
LI Xiu-juan, WANG Ming-wei, SONG Shao-dong, KANG Zi-hua
Received:
Revised:
Online:
Published:
李秀娟,王明伟,宋绍栋,康自华
作者简介:
Abstract:
The principle and operation of the low-voltage real-time protection system for the lower hybrid current drive (LHCD) system on HL-2A tokamak has been presented. The real-time protection is carried out by hardware circuits which must be reliable with response time less than 1μs. The real-time protection for wave guide arcing protection, klystron body-current protection and over-current protection of klystron collector had been realized in the LHCD experiments using single klystron in 2004. Special detector for each protected target was used . The precision of body-current detector reaches 0. 7 %. The protection system works reliably.
Key words: Arcing , Body-current , Over-current
摘要:
介绍了 HL-2A装置低杂波加热系统中的低压部分实时保护系统的原理和工作情况。实时保护电路工作可靠, 系统低压部份响应延迟时间小于 1μs。在 2004年的单只速调管实验中, ,速调管管体电流和速调管集电极过流进行了实时保护, 各个保护对象都有专用的探头进行测量, 其中管体电流探头精度达到 0. 7%。实验信号的分析表明保护系统的设计达到了实验要求, 有效地保护了实验对象。
关键词: 拉弧打火, 管体电流, 过流
CLC Number:
TL62 + 9
LI Xiu-juan, WANG Ming-wei, SONG Shao-dong, KANG Zi-hua. Performance of the LHCD low-voltage real-time protection system on HL-2A tokamak[J]. NUCLEAR FUSION AND PLASMA PHYSICS, 2006, 26(1): 27-30.
李秀娟,王明伟,宋绍栋,康自华. HL22A装置低杂波系统低压实时保护性能分析[J]. 核聚变与等离子体物理, 2006, 26(1): 27-30.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hjby.ac.cn/EN/
https://www.hjby.ac.cn/EN/Y2006/V26/I1/27
[1] 王明伟, 宣伟明, 杨懋永 ,等.高压调制器在LHCD系统中的长脉冲运行[R].核工业西南物理研究院年报, 1998.
[2] 马守全编.微波技术基础[M].北京:中国广播电视出版社, 1989.
[3] 饶军,刘永,袁勇,等. HL-1M装置LHCD系统双管运行及长脉冲实验[J ].核聚变与等离子体物理,1999 , 19 (2) :83. [4] 余利木.波加热及电流驱动实验的保护系统[R].核工业西南物理研究院年报,1992. [5] Landau L D , Lifshitz E M. The classical theory of fields (4th ed) [M].北京:世界图书出版公司,1999. 105. [6 ] 黄继昌主编.电子元器件应用手册光敏器件[M].北京:人民邮电出版社,2004.