Welcome to Nuclear Fusion and Plasma Physics, Today is Share:

Nuclear Fusion and Plasma Physics ›› 2021, Vol. 41 ›› Issue (s2): 527-532.DOI: 10.16568/j.0254-6086.2021s2018

Previous Articles     Next Articles

Development of the preliminary vacuum ultraviolet spectroscopy on HL-2M tokamak

ZHANG Kai, ZHENG Dian-lin, DONG Chun-feng, SUN Ping, FENG Lei, SHI Zhong-bing    

  1. (Southwestern Institute of Physics, Chengdu 610041) 
  • Received:2021-05-14 Revised:2021-07-30 Online:2021-11-15 Published:2022-01-10

HL-2M 真空紫外光谱初始诊断系统研制

张 凯,郑典麟,董春凤,孙 平,冯 雷,石中兵   

  1. (核工业西南物理研究院,成都 610041) 
  • 作者简介:张凯(1983-),男,湖南郴州人,博士研究生,从事等离子光谱诊断和杂质输运研究。
  • 基金资助:
    国家重点研发专项(2017YFE0301306);国家磁约束聚变能研究专项(2014GB108003) 

Abstract: HL-2M vacuum ultraviolet (VUV) spectral diagnostic system is developed based a combination of 
multiple Seya-Namioka spectrometers, each with an exchangeable grating. Due to an optimization in gratings, the 
wavelength coverage of the whole spectral system is 300Å to 3000Å with temporal resolution better than 1µs. 
After structural design and fabrication, spectral calibration and commissioning, a single channel VUV 
spectrometer was successfully set up in HL-2M tokamak, viewing horizontally from a midplane port. Spectral 
lines of impurity species (C, O, N) were observed in HL-2M first plasma discharges by the spectrometer, which 
showed excellent signal-to-noise ratio and high sensitivity. 

Key words: VUV, Impurity spectra, CEM, Hollow cathode light 

摘要: 基于 Seya-Namioka 结构 200mm 焦距可换光栅,研制了 HL-2M 真空紫外(VUV)光谱诊断光谱仪。该
系统在 300~3000Å 的真空紫外光谱范围具有较高的探测效率,时间分辨优于 1µs。经过结构设计、光谱标定和安
装调试,单通道 VUV 光谱仪已成功安装在 HL-2M 装置中平面窗口。在 HL-2M 装置初始放电实验中,利用该系
统测量到 C、O、N 等杂质的多条特征谱线,展现出优秀的信噪比和高灵敏度。 

关键词: 真空紫外光谱, 杂质光谱, 通道电子倍增管, 空心阴极灯

CLC Number: