Welcome to Nuclear Fusion and Plasma Physics, Today is Share:

NUCLEAR FUSION AND PLASMA PHYSICS ›› 2017, Vol. 37 ›› Issue (4): 446-451.DOI: 10.16568/j.0254-6086.201704013

• Nuclear Fusion Engineering and Technology • Previous Articles     Next Articles

High heat flux test and post examination of ITER divertor W/Cu monoblock mock-ups

SUN Zhao-xuan, LI Qiang, WANG Wan-jing, WANG Ji-chao, WANG Xin-li, WEI Ran, XIE Chun-yi, LUO Guang-nan   

  1. (1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031; 2. Science Island Branch of Graduate School, University of Science & Technology of China, Hefei 230031; 3. Hefei Center for Physical Science and Technology, Hefei 230022; 4. Hefei Science Center of Chinese Academy of Sciences, Hefei 230027)
  • Received:2016-10-08 Revised:2017-05-11 Online:2017-12-15 Published:2017-12-15

ITER偏滤器钨/铜穿管模块的高热负荷测试及事后分析

孙兆轩,李强,王万景,王纪超,王兴立,魏然,谢春意,罗广南   

  1. (1. 中国科学院合肥物质科学研究院等离子体物理研究所,合肥 230031; 2. 中国科学技术大学研究生院科学岛分院,合肥 230031; 3. 合肥物质科学技术中心,合肥 230022; 4. 中国科学院合肥大科学中心,合肥 230027)
  • 作者简介:孙兆轩(1990–),男,山东济宁人,硕士研究生,主要从事穿管型钨/铜模块的高热负荷性能研究。
  • 基金资助:

    国家自然科学基金(11305213)

Abstract:

High heat flux test of ITER divertor W/Cu monoblock mock-ups were finished. All tested mock-ups successfully withstood the heat cycles above and met the requirements of high heat flux performances specified by IO. After HHF test, the post analysis was performed on tested mock-ups. The results found the debonding of the Cu/CuCrZr interface and the crack of W. The scanning electron microscope (SEM) image of the break shows that intergranular rupture was the main mechanism of the W crack. The recrystallization was observed in the W monoblocks and the recrystallized depth was estimated by metallography analysis. The temperature distribution was also obtained by finite element analysis and a good correspondence with recrystallization observed by experiment was found.

Key words: ITER, High heat flux, Divertor, W/Cu mock-ups

摘要:

对ITER偏滤器钨/铜穿管模块进行了高热负荷测试。测试结果表明,所有的模块都成功承受住了热负荷测试并满足了IO的要求。在高热负荷测试后,对模块进行了事后分析。发现了钨的纵向开裂和Cu/CuCrZr界面的开焊现象。断口的SEM图像表明,钨的开裂方式为脆性的沿晶开裂。通过金相学分析,发现了钨的再结晶现象和钨表面的再结晶深度。还通过有限元分析软件模拟得到了模块的温度分布,并且与实验观察的再结晶现象能够很好的对应。

关键词: ITER, 高热负荷, 偏滤器, 钨/铜模块

CLC Number: