NUCLEAR FUSION AND PLASMA PHYSICS ›› 2006, Vol. 26 ›› Issue (1): 8-12.
• Contents • Previous Articles Next Articles
QIN Yun-wen
Received:
Revised:
Online:
Published:
秦运文
作者简介:
Abstract:
In tokamak plasma radiation diagnostics ,a relationship between the line-integrated emissivity and the plasma emissivity distribution in the infinitesimal-detector approximation is usually used. It can be shown that this approximation holds only for the detection system with the detector which has a poloidal size much smaller than that of the aperture. For the system with equal-size of detector and aperture, the cross-section of detector chord in plasma is twice as large as that in the infinitesimal-detector approximation. For such system the correction at finite detector size is derived for the line-integrated emissivity expression. The improvement by the correction on tomography analysis is discussed in brief.
Key words: Tokamak plasma , Line-integrated emisivity, Tomography analysis
摘要:
在托卡马克等离子体辐射的诊断中 ,线积分辐射率与辐射发射率之间的关系 ,常采用探测器无穷小近似下的表达式。简单分析表明 ,只有在探测器极向尺寸远小于光栏极向尺寸时 ,这种近似才成立。在探测器与光栏的极向尺寸相同的情况下 ,束线宽度约为探测器无穷小近似下的宽度的两倍。对这种探测系统的线积分辐射率作了有限探测器效应修正 ,并简要讨论了它对层析分析的影响。
关键词: 托卡马克等离子体 , 线积分辐射率 , 层析分析
CLC Number:
O536
TL65
QIN Yun-wen. Correction at finite detector size effect on line-integrated emissivity[J]. NUCLEAR FUSION AND PLASMA PHYSICS, 2006, 26(1): 8-12.
秦运文. 线积分辐射率的有限探测器效应修正[J]. 核聚变与等离子体物理, 2006, 26(1): 8-12.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hjby.ac.cn/EN/
https://www.hjby.ac.cn/EN/Y2006/V26/I1/8
[1] Granetz R S ,Smeulders P. X-ray tomography on JET [J].Nucl. Fusion ,1988 ,28(3) :457. [2] 秦运文.托卡马克等离子体辐射诊断中的线积分辐射率[J ].核聚变与等离子体物理,1999 ,19(1) :9.