欢迎访问《核聚变与等离子体物理》官方网站,今天是 分享到:

核工业西南物理研究院 ›› 2024, Vol. 44 ›› Issue (1): 30-35.DOI: 10.16568/j.0254-6086.202401006

• 核聚变工程 • 上一篇    下一篇

负离子源中性束注入器智慧能源管理系统设计

丁  健1,李逸斌1, 2,蒋才超2,宋士花*2,刘  胜2, 段  练2, 3,徐康幸1,刘智民2,谢远来2   

  1. (1.合肥学院先进制造工程学院,合肥 230601;2.中国科学院合肥物质科学研究院等离子体物理研究所,合肥 230031;3.安徽大学物质科学与信息技术研究院,合肥 230601)
  • 收稿日期:2022-06-15 修回日期:2023-10-15 出版日期:2024-03-15 发布日期:2024-03-13
  • 通讯作者: 宋士花(1980-),女,山东临泽人,高级工程师,硕士,从事中性束系统相关测控技术研究。
  • 作者简介:丁健(1971-),男,安徽宿州人,教授,硕士,从事网络化控制、嵌入式系统研究。
  • 基金资助:
    聚变堆主机关键系统综合研究设施项目(2018-000052-73-01-001228)

Design of intelligent energy management system for negative ion source neutral beam injector

DING Jian1, LI Yi-bin1, 2, JIANG Cai-chao2, SONG Shi-hua2, LIU Sheng2, DUAN Lian2, 3, XU Kang-xing1, LIU Zhi-ming2, XIE Yuan-lai2   

  1. (1. School of Advanced Manufacturing Engineering, Hefei University, Hefei 230601; 2. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031; 3. Institute of Physical Science and Information Technology, Anhui University, Hefei 230601)

  • Received:2022-06-15 Revised:2023-10-15 Online:2024-03-15 Published:2024-03-13

摘要: 为保障负离子源中性束注入(NNBI)系统用电的电能质量和稳定性,设计一套智慧能源管理系统。该系统以西门子PLC及分布式I/O系统为控制核心,通过对供配电系统各回路状态监控,基于Modbus通讯协议与多功能表的信息交互,实现对用电系统能耗监测及管理。通过可视化人机交互界面设计,为实验运行人员提供直观便捷的系统状态诊断工具。该系统具备一定的兼容性和扩展能力。相关台面测试表明,智慧能源管理系统运行稳定,控制可靠,能满足供配电系统的智能化管理和监测需求。

关键词: 中性束注入, 智慧能源管理系统, Modbus通讯, 人机交互界面

Abstract: A set of intelligent energy management system has been designed to ensure the stability and quality of power supplied to the negative ion source neutral beam injection (NNBI) system. This system utilizes a Siemens programmable logic controller (PLC) in combination with a distributed input/output (I/O) system that continuously monitors the operational status of the power supply system circuits. The Modbus communication protocol is implemented to interact with multifunctional energy meters for this purpose. Additionally, an intuitive human-machine interface design has been incorporated into the system to provide the experiment operators with a convenient tool to assess the system status directly. This intelligent energy management system has a certain degree of compatibility and scalability. The test results show that the system is stable and reliable, and effectively fulfills the requirements for the NNBI system.

Key words: Neutral beam injection, Intelligent energy management system, Modbus communication, Human- computer interaction interface