HL-3装置测量基准网的建立及部件定位测量

赖春林,刘  健,蔡立君,刘宽程,张  龙,HL-3研制团队   

  1. (核工业西南物理研究院,成都 610041)
  • 收稿日期:2022-04-02 修回日期:2023-10-24 出版日期:2024-03-15 发布日期:2024-03-13
  • 作者简介:赖春林(1986-),男,四川广汉人,硕士,工程师,主要从事托卡马克装置工程设计、制造及高精度装配技术研究。
  • 基金资助:
    四川省科技厅应用基础研究计划(2020YJ0183);西物创新行动项目(202102XWCXRZ001)

Establishment of datum network and component positioning measurement of HL-3 tokamak

LAI Chun-lin, LIU Jian, CAI Li-jun, LIU Kuan-cheng, ZHANG Long, HL-3 Development Team   

  1. (Southwestern Institute of Physics, Chengdu 610041)
  • Received:2022-04-02 Revised:2023-10-24 Online:2024-03-15 Published:2024-03-13

摘要: 根据HL-3装置总装集成设计安装精度的要求,需要建立一个高精度的测量基准网,在总装过程中采用激光跟踪仪等先进测量设备对安装部件的空间位置进行测量。建立的基准网实现了网内基准点空间坐标最大不确定度为0.133mm。特别在对真空室、临时第一壁/限制器等部件的安装中,进行定位测量和数据反馈,然后再进行安装调整,实现了真空室Æ1.84mm的同轴度精度,满足同轴度≤Æ3mm的要求;标高偏差为–0.08~+0.136mm,满足标高偏差≤±1mm的要求。临时第一壁/限制器安装最大偏差值为+1.9351mm,最小偏差值为–1.8337mm,均满足各模块表面位置误差不超过±2mm的技术要求。测量基准网的建立以及安装过程中对部件高精度的定位测量,保证了HL-3装置高质量的建造。

关键词: HL-3, 基准网, 部件定位测量, 激光跟踪仪

Abstract: According to the installation accuracy requirements of HL-3 assembly design, it is necessary to establish a high-precision datum network and adopt advanced measuring equipment such as laser tracker to measure spatial position of the installed components. The established datum network realizes the maximum uncertainty of the spatial coordinates of the reference points in the network to be 0.133mm. Especially, during the installation of vacuum vessel, temporary first wall/limiter and other components, positioning measurement, data feedback, installation and adjustment are carried out to achieve installation coaxiality of vacuum vessel in Æ1.84mm, which meets the coaxiality within Æ3mm; elevation deviation is between –0.08 and +0.136mm, which meets the elevation deviation within ±1mm. The maximum deviation of temporary first wall/limiter installation is +1.9351mm and the minimum deviation is –1.8337mm, which meets the surface position error of each module in ±2mm. The establishment of datum network and high-precision positioning and measurement of components ensure high-quality construction of HL-3 tokamak.

Key words: HL-3, Datum network, Component positioning measurement, Laser tracker